Interties

Real-time net flows and hourly transfer capability on the Alberta interties, pulled directly from AESO's Current Supply Demand report and Interchange ATC API. Positive values mean Alberta is exporting; negative values mean Alberta is importing. No synthetic modelling is used on this page.

Live snapshot from AESO CSD / ATCAs of approx. 2026-10-16, 14:12:18 AB time
System Net Actual Interchange
926 MW

From the CSD summary row "Net Actual Interchange". Positive = net export from Alberta; negative = net import into Alberta.

AB-BC Path
856 MW

Export from Alberta with British Columbia. Positive = exports from Alberta; negative = imports into Alberta.

AB-MATL Path
-81 MW

Import into Alberta with Montana (MATL). Positive = exports from Alberta; negative = imports into Alberta.

AB-SK Path
151 MW

Export from Alberta with Saskatchewan. Positive = exports from Alberta; negative = imports into Alberta.

Today's Intertie ATC by Hour

Hour-ending capabilities from AESO's Interchange ATC API (dataType=ATC) for 2026-10-16. Import / export ATC are shown in MW for each path and for the combined BC+MATL flowgate and provincial system.

HEBC Import ATCBC Export ATCMATL Import ATCMATL Export ATCSK Import ATCSK Export ATCBC+MATL Import ATCBC+MATL Export ATCSystem Import ATCSystem Export ATC
HE 017509502953001531534819351,1981,088
HE 027509502953001531534799351,1981,088
HE 037509502953001531534779351,1981,088
HE 047509502953001531534799351,1981,088
HE 057509502953001531534779351,1981,088
HE 067509502953001531535069351,1981,088
HE 077509502953001531534849351,1981,088
HE 087509502953001531534899351,1981,088
HE 097509502953001531534019351,1981,088
HE 10635935001531533979351,1981,088
HE 11750950001531534209351,1981,088
HE 12750950001531534199351,1981,088
HE 13750950001531534199351,1981,088
HE 147509502953001531534199351,1981,088
HE 157509502953001531534189351,1981,088
HE 167509502953001531534199351,1981,088
HE 177509502953001531534199351,1981,088
HE 187509502953001531534189351,1981,088
HE 197509502953001531533959351,1981,088
HE 207509502953001531533959351,1981,088
HE 217509502953001531534109351,1981,088
HE 227509502953001531534109351,1981,088
HE 237509502953001531534069351,1981,088
HE 247509502953001531534069351,1981,088

Data source: AESO Interchange ATC API (itc.aeso.ca/itc/public/api/v2/interchange, dataType=ATC). These are the same curves that back your Excel "Provincial Available Transfer Capacity" sheet – you can append additional derived columns (TRM, expected provincial flow, "we can" MW, etc.) in your own model or a future backend job without introducing synthetic inputs.